Back to top
Send SMS Send Inquiry

TAN SWA PDB AND APFC PANELS

TAN SWA PDB AND APFC PANELS
TAN SWA PDB AND APFC PANELS
Send Inquiry
Product Code : Tanswa_6
Brand Name : TAN SWA
Product Description

TAN SWA PDB AND APFC PANELS

We supply Low Voltage Power Distribution Boards (PDB), Breaker Panels, Automatic Power Factor Correction (APFC) Panels, Sub Distribution Panel, MCB DB for different industries.

PDB Panels are used for Electric Power Distribution, Fault Protection and Monitoring of different Electrical Systems. It usually consists of Incomer ACB/MCCB, Switch Fuse Unit (SFU), ELCB, MCCB, MCB etc.

Any Electrical Systems containing Inductive & Capacitive Loads consumes both Active and Reactive Power. APFC Panels are required to improve Power Factor of the entire plant/facility so that Total Power Consumption (Active + Reactive) is minimized. It is usually achieved by means of Capacitor Banks which are switched on & off based on real time Inductive Loads such as Induction Motors. Nowadays APFC Unit has become a necessity as many Power Distribution Companies have started charging penalties in case of Power Factor Drop beyond a limit.

Salient Features of our PDB & APFC panels are:

  • Compartmentalized ACB/MCCB & APFC Section
  • Expertise with mounting & wiring of different types of ACBs/ MCCBs upto 2000A
  • Capability of manufacturing APFC panels up to 1600A
  • In house Busbar Cutting, Busbar Bending, Sleeving Facility
  • User friendly enclosure design
  • Compliance to safety norms
  • Testing Facility with 3-Phase Power Supply
  • Upto IP 54 Protection Available
  • Four Quadrant Measurement
  • Accuracy of +0.8% for Reactive Power, + 0.5% for Current 6 or 12 steps to operate Capacitor Circuits.
  • Precise and quick relay controls
  • Continuous monitoring of defective capacitor stages.
  • Counting, Storing and Display of number of switching operation
  • Alarm for excess operation than programmed limits.
  • Dual control curve characteristics: to avoid over compensation under light loads and to avoid inductive reactive power under regenerative conditions.
  • Monitoring of harmonic levels continuously with alarm and safety trip facility.
  • Zero voltage & Zero current tripping with alarm signals
  • Manual/Automatic operation with ability to switch each individual Capacitor

Being located in Navi Mumbai, Our supplied Panels are working not only in India but also in various countries like Dubai, Qatar, Saudi Arabia KSA, Oman, Kuwait and also in Austria, Germany, USA, Australia, Sri Lanka, Singapore, Malaysia, Vietnam, Indonesia, India, Nigeria, China, South Korea, Bangladesh, Zambia etc

 

PDB Panels are used for Electric Power Distribution, Fault Protection and Monitoring of different Electrical Systems. It usually consists of Incomer ACB/MCCB, Switch Fuse Unit (SFU), ELCB, MCCB, MCB etc. Any Electrical Systems containing Inductive & Capacitive Loads consumes both Active and Reactive Power.

APFC And PDB Panels

Electrical loads such as motors can cause electrical systems to be very inductive, which results in very lagging power factor i.e. wastage of energy. The simple solution to maintain the power factor in required range is to connect or disconnect the power factor correction capacitors. Manual switching is just impossible for rapidly fluctuating loads and hence an automatic control system is required which continuously monitors the power factor and make appropriate corrections to maintain it within the required range.

System Design:

iPOWER Automatic Power Factor Correction System is unique with its Custom Based Design, based on the Load Study Conducted on site with High Speed Power Quality Analyzer with recording interval selected as appropriate to the study, depending on the Loading pattern.

The System is basically designed as a series RLC Circuit to suppress the transient inrush current, while injecting reactive current. Its Components Selection is critical due to the inherent operating parameters of the Capacitors which draws high inrush current during switching and while opening out. The Electrical charges remains in the capacitor thereby building up the Restriking Voltage. This characteristics of the Capacitors needs careful study and selection of the correct components to ensure long life for the total system.

The choice of capacitor duty contactors with damping resistors provide protection from inrush current during switching. The coil wound inductors provide additional protection from short time high current peaks. The sequential cyclic switching of capacitors with preset time delay for safe discharge of capacitors, increases the life of capacitors and avoids problems rooting from voltage peaks while energizing the charged capacitors at sinusoidal peak instants of supply voltage.
The selection of capacitor stages with appropriate stage ratios matching the load profile provides power factor correction with high-resolution.

PRODUCT SHOWCASE

  • PDB PANEL WITH APFC SECTION: INCOMER- 630 A
  • DB PANEL: INCOMER- 1250 A
  • SUB DISTRIBUTION PANEL
  • APFC PANEL: 400 A
  • PDB PANEL: INCOMER- 400A

RELISERV SOLUTION
X


RELISERV SOLUTION
Office No.-9, Plot 53/54, Sector-34, Space Heights, Near Tawa Hotel, Kamothe, Navi Mumbai - 410209, Maharashtra, India
Mr Piyush Lalchand Rathi (Partner)
Mobile :+919819614841, +919769207841
Mr. Dnyanesh Gawande (Partner)
Mobile :+919833686249