GE / Alstom MiCOM Agile P443 Distance Protection System Numerical Relay

GE / Alstom MiCOM Agile P443 Distance Protection System Numerical Relay
GE / Alstom MiCOM Agile P443 Distance Protection System Numerical Relay
Send Inquiry
Product Code : P443
Product Description

GE / Alstom MiCOM Agile P443 Distance Protection System Numerical Relay

GE MiCOM Agile P443 and the MiCOM Agile P445 and P446 relays operate with advanced load blinding and disturbance detection techniques, such as power swing blocking, to ensure stability when no tripping is required. Whether protection is required for lines, cables or hybrids of grounded transmission and distribution circuits, the MiCOMho Agile P443, Alstom P443, P445 and P446 relay characteristics allow for versatile deployment.

Alstom P443 Key features:
• MiCOM P443 & P446: True subcycle distance protection with transmission class security and dependability
• Unparallelled speed, security and selectivity
• Extremely versatile logic capabilities, managing leader-follower auto-reclosing and check synch schemes in dual breaker applications
• Transmission-class circuit breaker failure protection for one or two breakers. The breaker failure protection may be initiated from internal protection within the relay or from external devices
• Single-pole and 3-pole breaker operation is supported, with independent supervision and condition monitoring statistics for each pole
• Trip circuit supervision, control and interlocking schemes can be designed via graphical support software
• No internal batteries in GE-branded models – removes a maintenance item and eases air-freight logistics
• NERC CIP cybersecurity
• Binary inputs ESI48-4 EB2 compliant

Transmission and distribution systems are essential for the safe, sure routing of power from generation sources to consumers. However, exposed overhead lines transporting power are by nature sometimes vulnerable and prone to fault. In the case of a faulty circuit, the Agile range provides speedy protection to trip and isolate it, thereby preventing further damage.

Each relay model contains multiple main protection elements: distance, delta directional incremental protection and directional earth/ground fault unit protection (DEF). This permits simplified application and spares holdings, because the relay can be adopted as the standard protection platform.

The MiCOMho Agile P443 and P445 are suitable for feeders controlled by a single circuit breaker. The MiCOMho Agile P446 is suitable for complex installations where feeders are controlled by two circuit breakers such as ring bus/mesh corner formations and the breaker-and-a-half configurations.

Key benefits:

  • P443 and P446: Sub-cycle fault clearance from 0.7 to 1 cycle
  • Simple set mode: The relay determines its own settings from protected line data
  • Power swing blocking without the need for setting
  • Integral teleprotection via a MODEM, fiber or MUX channel
  • Fast CB failure resetting (<3/4 cycle)
  • Phase-preference tripping for cross-country earth faults in Petersen/isolated systems (P443 version 92)

We offer GE’s century long tradition of power system innovation. From generators to transmission lines, to motors and beyond, we ensure dependable, safe power worldwide. GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems. Explore GE numerical Relays portfolio with us!